search

2016年12月15日星期四

Stainless steel submersible pump installation diagram

First, the installation of stainless steel submersible pump diagram
Stainless steel submersible pump installation diagram.jpg

Second, the cable connector method
(one)
1: Remove the insulation layer, must not damage the conductor.
2: three wires are staggered
3: scraping the conductor insulation film
4: to ensure that the joint does not exist oil, water and its objective existence of dirt.

(two)
1: the joints for the number of paragraphs (not less than six shares) evenly separated.
2: Cross the two connectors together. Cross-length to the ends of the line is aligned with the insulating layer is appropriate.

(three)
1: the units together, from which an end to a carbonyl winding finished.
2: The other end in the same way.
3: with the pliers to tighten the joints, the conditions of the tin-linked joints, so that better results.

(four)
1: first with ordinary black tape wrapped around the winding part of the two, dressing is important.
2: Yamin adhesive tape (black) dressing three layers, each banding a hand squeeze a layer to ensure the quality of dressing.
3: Finally, with plastic insulation bandage can be two layers.

(Fives)
1: first finishing a small connector, with a sub-sensitive adhesive tape bandage of five, (not less than four), and to keep the cable jacket part of more than 25mm.
2: three layers of plastic insulation tape, both ends more than 5mm above the previous layer.
3: In order to prevent the next break when the import of rubbing bandage, it is best to use 50mm wide, appropriate length of the inner tube of the bicycle, filing the net on both sides, coated with glue, wrapped in a layer outside the joints, from the protective effect.
 (six)
The use of arc welding joints can also be used better casing method of cold-pressing joints in the first layer of black tape, not allowed to wire head exposed or Zaotu tape.

Precautions:
1: To check the insulation of the motor, please check the insulation of the motor. The cable must be in accordance with the instructions. After the connector is wrapped, it must be immersed in water at room temperature for 12 hours, then insulation can be measured.
2: two kinds of tape are flexible, bandage should be tightened, the last layer of wrap around the original after a few laps to prevent long after the release.
3: Each joint in the dressing, when the tape must be wound layer 5mm above the previous layer.
4: bandage three single-core guide wire, the sub-sensitive tape rolled into a triangle shape into the gap Department. Prevention of infiltration in water.