search

2016年12月18日星期日

Fountain pump maintenance should pay attention to matters

service.jpg
Fountain pump repair should pay attention to what the fountain pump repair and inspection of the best by professional technical staff to deal with, if it is a special case, in the case of minor problems can be handled on its own, when it comes to power supply or It is recommended that maintenance should be performed by a qualified person in order to avoid any accident.

    Then in the need to pay attention to what the fountain pump repair it, this article for everyone to do under the introduction

   Repair fountain pump before the preparatory work, repair fountain pump before the precautions

    First, overhaul the construction project content validation

       (1) repair fountain pump before the work should implement the fountain pump number and maintenance category, namely, a clear location and the equipment is the equipment overhaul, repair, minor repairs in which, or unplanned maintenance, and unscheduled maintenance s reason.

     (2) access to equipment maintenance records, to understand the situation before the equipment overhaul, fountain pump on the history and status of the comprehensive analysis, be aware of.

    Second, the maintenance program and open parking program implementation

       According to the above content to develop this maintenance procedures, maintenance of the main content and location and to take specific methods.

        Equipment maintenance generally use two methods: one method is the partial surrender, that is, start the backup equipment, the equipment should be cut out of the operating system: Another method is to stop all the equipment for maintenance. But no matter which method, due to the characteristics of petrochemical production, must be strictly to develop equipment to hand over procedures. For example, in the process of cutting off the production system, the remaining flammable, explosive, toxic and hazardous substances in the equipment, power supply cut-off, residual pressure inside the equipment, on-site maintenance environment must be strictly. Any kind of overhaul includes parking, processing handing over, testing, driving the process, must develop a detailed program, the progressive implementation of the equipment can ensure smooth maintenance.

    Fountain pump maintenance

   Implementation of spare parts and other supporting materials

    (1) preparation of spare parts.

    Based on a comprehensive understanding of the various pump products to determine the possibility of replacement parts, spare parts must be implemented in advance, from the spare parts management office out, and the necessary checks. Spare parts must have a quality certificate, not to mention the wrong collar.

    (2) the preparation of other auxiliary materials.

 Other auxiliary materials, such as gaskets, lubricants, fasteners, pipe valves, wiping machine cloth, cotton yarn, etc., which must be used during the inspection and maintenance, must be accurate in their names, specifications and quality.

   Fourth, the implementation of maintenance tools and equipment

    (1) maintenance equipment necessary general tools for the preparation.

    Wrench, screwdriver, screwdriver, screwdriver, screwdriver, hand scissors, flat scraper, electric knife, oil scraper, flat shovel and other specifications to be complete.

    (2) special equipment for the preparation.

    Such as pull plate or pull claws, the top hole pad, hanging frame, plus the jacket of the hook and other homemade special equipment.

   (3) the maintenance of the equipment required for the preparation.

Such as welding machine, pressure pump, hand wheel, etc., these devices must be identified in advance, really safe and reliable, to avoid affecting the smooth progress of maintenance work.

    (4) preparation of lifting appliances.

    Such as hanging chain, jack, dowm, wire rope and so on.

    (5) the necessary measuring tools, cutting tool preparation.

    Such as micrometer, vernier caliper, dial indicator, steel ruler, tap, wrench, specifications, accuracy to meet the needs of maintenance.

  Fifth, the security operation in the maintenance

    (1) labor protection products, such as overalls, hats (single work cap or helmet), gloves, labor insurance shoes, to be neatly dressed to meet the requirements.

    (2) hand-held hammer or hand-held power tools are not allowed to wear gloves, but holding a flat shovel to wear gloves.

    (3) before using the hammer to carefully check the hammer is solid and reliable installation, when playing around to pay attention to whether someone was hammer.

    (4) When using the wrench to clamp the nut, do not use force to prevent slippage, the occurrence of bump injuries.

    (5) lifting parts, rope buckle, rope sets must be strong and reliable, hanging material to fasten. Grasp the center of gravity balance, adjust the center of gravity, be sure to put down after hanging objects.

    (6) hanging under the person is strictly prohibited station, lifting, falling, the speed may not move too fast, there must be hand command.

    (7) two or more carry carry parts, it is necessary to coordinate action, play hello to each other to prevent accidents.

    (8) operation shall not be slapstick, laughing or chatting, be sure to concentrate, concentrate.

    The above details for everyone in the fountain pump repair should pay attention to the matter, I hope you can carefully read, only really do these can be fountain pump maintenance foolproof, does not appear unexpected. Perhaps the summary of this article is not comprehensive enough, but I hope everyone will help.