search

2016年12月8日星期四

How to improve the self-suction capacity of non-clogging sewage pump?


Here are several methods to improve the self-suction capacity of non-clogging sewage pump:
Method one: set vacuum pump on the suction piping of water pump. Start the vacuum pump before starting the water pump to make the suction piping full of water and ensure the water pump starts automatically and quickly.
Method two: reduce the bending, drop height and horizontal spacing of suction piping of non-clogging sewage pump.
Method three: set pump suction tank. Set a water tank on the suction piping of water pump and the tank should be filled with water before the first operation.
Method four: install suction bottom valve at the end of suction piping of sewage pump. Suction bottom valve is actually a kind of check valve, which will ensure water flows into the suction piping through water tank without backflow. It can ensure water pump starts automatically and quickly.

Keywords:No clogging sewage pump, self - priming ability