How to check the installation of stainless steel deep well pump?


Vertical stainless steel deep-well pump before the installation, should respond to the vertical wells and the curvature and well water to check.

(1) Verticality and curvature of the deep well Before installing the stainless steel deep well pump, the verticality and curvature of the deep well should be checked to ensure that the shaft of the stainless steel deep well pump has a vertical position after it is installed in the deep well. This requires deep well pipe from the wellhead to install water pump section where the location of the vertical should be. Even if the deviation from the vertical position of the well, its deviation should also be controlled in a certain range, so that stainless steel shaft drive shaft in the well can still maintain vertical operation.

(2) well water inspection Before the installation of stainless steel deep-well pump, should also check the upper part of the well water and the presence of oil and its emulsions. To prevent the installation of stainless steel deep-well pump test run, the oil and emulsion attached to the pump and the shaft of the rubber bearings, the production of adverse effects. Often can be used rope hoisted keg into the deep well, the water surface suspended oil impurities and other wells.

In addition, Shenlong pump here to explain to our customers about the stainless steel deep-well pump motor wiring.

1) Check the stainless steel deep-well pump motor wiring, the motor oil chamber should first be filled with oil: Unscrew the oil hole plug, from the oil hole to join the 10 oil to the middle of the oil marked instructions. Do not operate the motor or overfill the motor.

2) The motor base should be properly and reliably grounded.

3) According to the specified wiring method of the motor, correctly connect the stator windings.

4) Check the direction of the motor, the correct steering is: When the power phase sequence and the motor phase sequence is opposite from the top of the motor as the direction of its rotation should be counter-clockwise.

5) The motor control device should generally have over-current protection, short-circuit protection device or overheating protection device, the motor should be based on the rated current value of the protection device to adjust the current value.
Keywords:Stainless steel deep well pump, installation inspection