Analysis and Treatment of Fuse Breaking of Small Stainless Steel Submersible Pump


Small stainless steel submersible pump access to power, the fuse is broken and the power supply voltage is too low, water pumps and motor failures and improper use.

1) small stainless steel submersible pump two-phase operation, should check the reasons for the two-phase operation of submersible pump. Treatment is: as a result of the two-phase power failure, repair damaged power supply; as a result of submersible pump failure, should be submersible pump failure to check and repair.

2) small stainless steel submersible pump impeller blocked by debris, friction, handling is to remove the submersible pump, pump impeller or removal of debris in the flow channel, the submersible pump rotation smooth, light.

3) The power supply voltage is too low The power supply voltage is too low so that the submersible pump can not start processing method is to adjust the power supply voltage to 320V-400V, the submersible pump can be successfully started.

4) small stainless steel submersible pump motor bearing damage. Motor bearing damage, will make the submersible pump can not be used normally, the current becomes larger. Treatment is to replace the damaged submersible pump bearings.

5) small stainless steel submersible pump turn bearing bending, stator and rotor heart. This is a serious failure, will make the submersible motor air gap, the bearing force deterioration, and even make submersible pump stator and rotor phase wipe, so that when the diving operation produces severe vibration, should be immediately overhauled, straight bending Of the shaft, the replacement of inappropriate bearings.